This guide covers VPOS Media pulse configurations, including Single Price per Line Mode for fixed-cost setups and Multi Price Mode for flexible pricing through pricelists.
General
This guide explains how to set up pulse-based machine control on VPOS Media 4 and Media 4 Mini devices. Use it to configure single-price or multi-price vending through your Nayax Core machine profile.
Single Price Mode offers a fixed-price setup for machines providing one service at one set cost. Ideal for photo booths, kiddie rides, and standard vending delivering a simple, fast configuration with no customer price selection required.
Multi Price Mode supports flexible pricing with price lists and pulse-based machine communication. Pulses are brief electrical signals defined by duration and frequency, used to trigger vending actions.
| VPOS Media Pulse Configuration Quick View | ||||
|
Parameter |
VPOS Media 4
|
|
Explanation |
Attribute |
|
SINGLE PRICE CONFIGURATION
|
||||
| Credit per Pulse 1-6 (Cents) | 100;0;0;0;0;0 | 100;0;0;0;0;0 | 631 | |
| Number of Pulses per Vend 1-6 | 1;0;0;0;0;0 | 1;0;0;0;0;0 | The number of pulses need to be sent for activating the machine. | 632 |
| Pulse IN 1-6 Counter | Enable as needed | Enable as needed | 634 | |
| Pulse 1-6 Active Time (ms) | 10;0;0;0;0;0 | 100;0;0;0;0;0 | 635 | |
| Pulse 1-6 Inactive Time (ms) | 10;0;0;0;0;0 | 100;0;0;0;0;0 | 636 | |
| Post Delay per Pulse 1-6 (sec) | 15 | 15 | Delay before next transaction is accepted | 637 |
| Inhibit Event Timeout (sec) | 90 | 90 | 658 | |
| Pulse Inhibit | 00 – Inhibit Disabled
(Nayax ignores inhibit) |
00 – Inhibit Disabled
|
Leave at 00 unless hardware inhibit is wired | 657 |
|
Parameter |
VPOS Media 4
|
|
Explanation |
Attribute |
|
MULTI PRICE CONFIGURATION
|
||||
| Credit per Pulse 1-6 (Cents) | 100;0;0;0;0;0 | 100;0;0;0;0;0 | 631 | |
| Number of Pulses per Vend 1-6 | 1;0;0;0;0;0 | 1;0;0;0;0;0 | The number of pulses need to be sent for activating the machine. | 632 |
| Pulse IN 1-6 Counter | Enable as needed | Enable as needed | 634 | |
| Pulse 1-6 Active Time (ms) | 100;0;0;0;0;0 | 100;0;0;0;0;0 | 635 | |
| Pulse 1-6 Inactive Time (ms) | 100;0;0;0;0;0 | 100;0;0;0;0;0 | 636 | |
| Post Delay per Pulse 1-6 (sec) | 0;0;0;0;0;0 | 0;0;0;0;0;0 | Delay before next transaction is accepted | 637 |
| Pulse Title (1-6) | %c 2Min ; %c 5Min ;
%c 10Min ; %c 13Min |
%c 2Min ; %c 5Min ;
%c 10Min ; %c 13Min |
On-screen time labels Optional | 639 |
| Pulse Increment Prices (Cents) | 200, 400, 800, 1000
($2 / $4 / $8 / $10) |
200, 400, 800, 1000
($2 / $4 / $8 / $10) |
Maps increment steps to dollar price points | 641 |
| Inhibit Event Timeout (sec) | 90 | 90 | Default for notification alert to operator | 658 |
| Pulse Inhibit |
Default
|
Default
00 – Inhibit Disabled (Nayax ignores inhibit) |
For Media Devices limited to default or:
01 - Inhibit Enabled and Active on logic 0 received from VMC |
657 |
| Pulse Increment | 2,5,8,13 | 2,5,8,13 | Defines increment steps for multi-price selection between products/service | 663 |
| Pulse Options | 03 – Use Price Array
For Outgoing & Incoming Pulses |
03 – Use Price Array
For Outgoing & Incoming Pulses |
Required to activate the multi-price array | 722 |
| Values shown are Nayax recommended defaults | ||||
- BASIC = minimum required fields. These templates contain only the essential configuration.
- Operators must add any additional attributes they require beyond this basic setup.
- Default Credit must always be set it pre-authorizes payment to cover purchases and prevents non-payment.
- After configuring each attribute, select its checkbox on the left. When ready, click Actions › Update Queue to push the changes to your device.
Additional Information
Did you find this article helpful?