Quick View Pulse Configuration | VPOS Media

This guide covers VPOS Media pulse configurations, including Single Price per Line Mode for fixed-cost setups and Multi Price Mode for flexible pricing through pricelists.

General

This guide explains how to set up pulse-based machine control on VPOS Media 4 and Media 4 Mini devices. Use it to configure single-price or multi-price vending through your Nayax Core machine profile. 

Single Price Mode offers a fixed-price setup for machines providing one service at one set cost. Ideal for photo booths, kiddie rides, and standard vending delivering a simple, fast configuration with no customer price selection required.

Multi Price Mode supports flexible pricing with price lists and pulse-based machine communication. Pulses are brief electrical signals defined by duration and frequency, used to trigger vending actions. 

 

VPOS Media Pulse Configuration Quick View

Parameter

VPOS Media 4
Values



VPOS Media 4 Mini

Values

Explanation

Attribute

SINGLE PRICE CONFIGURATION
Use Single Price mode when your machine offers one service at one fixed price
ie. a photo booth, kiddie ride, or basic car wash rinse

Credit per Pulse 1-6 (Cents) 100;0;0;0;0;0  100;0;0;0;0;0   631 
Number of Pulses per Vend 1-6 1;0;0;0;0;0 1;0;0;0;0;0 The number of pulses need to be sent for activating the  machine. 632
Pulse IN 1-6 Counter Enable as needed Enable as needed   634
Pulse 1-6 Active Time (ms) 10;0;0;0;0;0 100;0;0;0;0;0   635
Pulse 1-6 Inactive Time (ms) 10;0;0;0;0;0 100;0;0;0;0;0   636
Post Delay per Pulse 1-6 (sec) 15 15 Delay before next transaction  is accepted 637
Inhibit Event Timeout (sec) 90 90   658
Pulse Inhibit 00 – Inhibit Disabled
(Nayax ignores inhibit)

00 – Inhibit Disabled
(Nayax ignores inhibit)

Leave at 00 unless hardware inhibit is wired 657
 

Parameter

VPOS Media 4
Values



VPOS Media 4 Mini

Values

Explanation

Attribute

MULTI PRICE CONFIGURATION
Use Multi-Price mode when your machine offers multiple products or service durations, each activated by a different number of pulses. ie. a car wash with 2-minute, 5-minute, 10-minute, and 13-minute cycles

Credit per Pulse 1-6 (Cents) 100;0;0;0;0;0 100;0;0;0;0;0   631
Number of Pulses per Vend 1-6 1;0;0;0;0;0 1;0;0;0;0;0 The number of pulses need to be sent for activating the  machine. 632
Pulse IN 1-6 Counter Enable as needed Enable as needed   634
Pulse 1-6 Active Time (ms) 100;0;0;0;0;0 100;0;0;0;0;0   635
Pulse 1-6 Inactive Time (ms) 100;0;0;0;0;0 100;0;0;0;0;0   636
Post Delay per Pulse 1-6 (sec) 0;0;0;0;0;0 0;0;0;0;0;0 Delay before next transaction  is accepted 637
Pulse Title (1-6) %c 2Min ; %c 5Min ;
%c 10Min ; %c 13Min
%c 2Min ; %c 5Min ;
%c 10Min ; %c 13Min
On-screen time labels Optional 639
Pulse Increment Prices (Cents) 200, 400, 800, 1000
($2 / $4 / $8 / $10)
200, 400, 800, 1000
($2 / $4 / $8 / $10)
Maps increment steps to dollar price points 641 
Inhibit Event Timeout (sec) 90 90 Default for notification alert to operator 658
Pulse Inhibit

Default
00 – Inhibit Disabled
(Nayax ignores inhibit)

Default
00 – Inhibit Disabled
(Nayax ignores inhibit)
For Media Devices limited to default or:
01 - Inhibit Enabled and Active on logic 0 received from VMC
657
Pulse Increment 2,5,8,13 2,5,8,13 Defines increment steps for multi-price selection between products/service 663
Pulse Options 03 – Use Price Array
For Outgoing & Incoming Pulses
03 – Use Price Array
For Outgoing & Incoming Pulses
Required to activate the multi-price array 722
Values shown are Nayax recommended defaults
 
 
⚠ IMPORTANT NOTE  
  • BASIC = minimum required fields. These templates contain only the essential configuration.
  • Operators must add any additional attributes they require beyond this basic setup.
  • Default Credit must always be set it pre-authorizes payment to cover purchases and prevents non-payment.
  • After configuring each attribute, select its checkbox on the left. When ready, click ActionsUpdate Queue to push the changes to your device.
 

Additional Information

Did you find this article helpful?