Last Alert Codes, Definitions and Action | Nayax Energy

The Last Alerts report in Nayax Energy Core displays the alerts related to EV chargers and Nayax devices. Learn how to efficiently manage EV Last Alerts to understand and identify the cause of a malfunction.

General

While electric vehicle charging technology is remarkably reliable, occasional alerts and error messages are a normal part of ownership and most issues can be resolved in minutes without calling support.

What causes EV charger error codes? 

Electric vehicle chargers monitor dozens of safety parameters in real-time, from ground faults and temperature spikes to communication errors and power supply issues. When something falls outside normal operating range, your charger generates an alert code to protect both your vehicle and the charging equipment.

Most charging problems stem from just a handful of causes: tripped breakers, loose connections, ground fault issues, or temporary communication glitches. With the right knowledge, you can diagnose and resolve up to 80% of charger errors yourself saving time, money, and the frustration.

 

CONNECTIVITY & COMMUNICATION

Code

Event Name

Description

Recommended Action

991014

MQTT Connected

The device is successfully receiving data from the server.

No action required.

991013

MQTT Not Connected

The device is unable to receive data from the server.

Check connectivity and network configuration.

96

IP/DNS Connection Established

Connection to IP/DNS was successfully established.

No action required.

22

No Charge Point Communication

Internet communication with the charge point was lost.

  1. Reset the charge point.
  2. Power off for 2 minutes.
  3. Contact support if unresolved.

10

Charger Communication Error

Communication between charger and device was lost.

Restart the charge point. If the issue persists, contact support.

23

Vehicle Communication Failure

Communication between the charger and the vehicle was lost.

Restart the charge point and ensure the cable is fully inserted. Contact support if unresolved.

21

BLE Device Connected

Communication between AMIT and BLE device established.

No action required.

22

BLE Device Disconnected

Communication between AMIT and BLE device was lost.

  1. Upgrade to the latest AMIT firmware.
  2. Use the mobile app to verify BLE visibility.

109

Low RSSI Signal

Signal strength below threshold (RSSI < 10).

Contact support.

 

OCPP PROTOCOL

Code
Event Name
Description
Recommended Action
30
Boot Notification
Charge point was reset.
No action required.
38
Boot Notification Failed
Charger boot notification failed to reach the backend.
Contact support.
36
OCPP Authorize
OCPP authorization request processed.
No action required.
40
OCPP Server Error
An error was received from a third-party OCPP server.
Contact support.
501
WebSocket Closed (Heartbeat Missing)
OCPP connection closed due to missing heartbeat.
Perform a hard reset.
502
WebSocket Lost
OCPP server connection lost.
Perform a hard reset.
503
WebSocket Exit
WebSocket session exited unexpectedly.
Perform a hard reset.
504
WebSocket Error
Error detected in OCPP WebSocket connection.
Contact support.
510
Undefined Serial Number
WebSocket opened with undefined charger serial number.
Verify charger configuration.
511
WebSocket Connected
OCPP server connection established successfully.
No action required.
701
Remote Start Transaction
Remote command to start charging executed.
No action required.
702
Remote Stop Transaction
Remote command to stop charging executed.
No action required.
703
Reset Charge Station
Remote reset command executed.
No action required.
704
Change Availability
Charger availability status updated remotely.
No action required.
705
Unlock Connector
Connector unlock command executed.
No action required.
711
Get Configuration
Full configuration data retrieved from the charge point.
No action required.
712
Trigger Message
OCPP trigger message sent.
No action required.
714
Change Configuration
Charger configuration updated.
No action required.
715
Data Transfer
OCPP data transfer message processed.
No action required.
 

CHARGING SESSION MANAGEMENT

Code
Event Name
Description
Recommended Action
33
Start Transaction
Charging session started successfully.
No action required.
34
Stop Transaction
Charging session stopped.
No action required.
4081
Start Charging Failed
Charger failed to initiate charging.
Contact support.
31
Charger Status Update
Charger operational state update (Available, Preparing, Charging, Suspended EV, Suspended EVSE, Finishing, Reserved, Unavailable, Faulted).
If status is Faulted, contact support.
720
Set Current (Active Session)
Charging current adjusted for active session.
No action required.
721
Set Charging Profile
Charging profile applied to the charger.
No action required.
890
Charging Station Stop
Session Stopped as Authorization Amount Reached
No action required.
13
EV Telemetry
EV telemetry event recorded.
No action required.
 

CONNECTOR STATUS

Code
Event Name
Description
Recommended Action
14
Connector 1 Plugged In
Connector 1 (left) was plugged in.
No action required.
17
Connector 1 Unplugged
Connector 1 (left) was unplugged.
No action required.
15
Connector 2 Plugged In
Connector 2 (right) was plugged in.
No action required.
18
Connector 2 Unplugged
Connector 2 (right) was unplugged.
No action required.
16
Connector Plug In
Connector was plugged into the vehicle.
No action required.
19
Connector Plug Out
Connector was unplugged from the vehicle.
No action required.
 

PAYMENT & AUTHORIZATION

Code
Event Name
Description
Recommended Action
770
Card Type Not Supported
The device is not allowed to bill this type of card.
Verify that both the operator and the charge point support this payment method.
996
EMV Not Supported
The billing provider does not support EMV transactions.
Contact support.
18
Transaction Cancelled
Transaction was cancelled for an unknown reason.
Contact support.
29
Negative Prepaid Card Balance
The prepaid card balance is negative.
Go to Cards > Select Card > Change Credit, add credit, and confirm.
1
RFID Card Not Recognized
RFID card is not registered in the system.
Register the card using the decimal number shown in the event data.
2
RFID Card Blocked
RFID card is expired or inactive.
Go to Consumers > Cards and update the card status.
842
Card Not Allowed (Group Restriction)
Card usage restricted by charge point group configuration.
Go to Consumers > Cards and enable the relevant charge point group under limits.
1
AAC Report – Pre Authorization
Card reader failed to properly read the card.
Resend the Card Readers configuration to the charging station.
520
Account Billing Failed
Billing attempt failed for the account.
Add or update credit card details under the EV account.
521
Add Credit Card Failed
Failed to add a credit card to the account.
Retry or contact support.
 
 
 

ELECTRICAL & SAFETY

Code
Event Name
Description
Recommended Action
7
Leakage Current (RCD) Detected
Leakage current detected. Charging stopped. The EVSE will retry after 1 minute, up to 5 times.
Contact support.
4
High Temperature
Internal EVSE temperature exceeded 85°C. Charging will resume once temperature drops below 85°C.
Contact support.
6
High Voltage / Improper Grounding
Voltage exceeded ~270V (15% over nominal). Charging pauses until voltage normalizes.
Contact support.
12
Low Voltage
Low voltage detected, commonly during single-phase connection or charging.
Monitor power supply conditions.
11
Missing Phase
One electrical phase is missing.
Inspect power supply if persistent.
20
Ground Failure
Protective Earth (PE) wire is not connected.
Requires a qualified electrician to inspect PE wiring.
24
Relay B Failure – Single Phase Mode
Relay connecting phases 2 and 3 failed. Charging continues on one phase only.
Contact support.
8
Relay Malfunction
Internal relay malfunction detected (may be stuck open or closed).
Contact support.
 
 

SYSTEM & DEVICE MANAGEMENT

Code
Event Name
Description
Recommended Action
1
Application Restarted
Android application was restarted.
No action required.
31
Reboot
Device rebooted. If firmware was sent, it will be downloaded after boot.
Monitor device status post-reboot.
5
Remote Restart
Remote restart command executed.
No action required.
24
Charge Point Power Up
Charge point powered up.
No action required.
2
Door Open Event
EV meter back board was opened.
Inspect for unauthorized access if unexpected.
26
Reader State Error
Card reader fault detected; reset often resolves the issue.
1. Reset the charge point. 2. Contact support if unresolved.
135
POS Unexpected Failure
POS failure detected; device will reset automatically.
1. Reset the charge point. 2. Contact support if unresolved.
9
General Alert
General system alert reported.
Contact support for investigation.
 
 

FIRMWARE & CONFIGURATION

Code
Event Name
Description
Recommended Action
750
Firmware Version Mismatch
Main firmware version does not match the POS version.
Resend the firmware update to the device.
110
Firmware Update Successful
Firmware update completed successfully.
No action required.
713
Update Firmware
Firmware update command sent to the charger.
Monitor update progress.
803
FTP Download Completed
File download from the FTP server to the device completed successfully.
No action required.
601
DLM Configuration Missing
Board limitation configuration missing for Dynamic Load Management.
Verify DLM configuration.
 
 

Did you find this article helpful?