Cashless MDB address - This parameter defines the unit's communication protocol with the VMC.
MDB flags - This parameter will change the MDB "standard" behavior, with this parameter you can decide to work preauthorization or preselection.
Vend Result Timeout (MAX: 65535 sec) - This attribute defines the time in seconds that the unit will wait for a Vend Success/Failure report from the vending machine. The default value is set to 40 seconds.
MDB Communication time delay (ms) - This parameter defines a delay between the unit's power up and the start of the MDB communication with the machine.
Disable Sending Cash Sale Notification - This Parameter force the unit not to send cash transactions report to the server. Doing so will cause cash transactions to disappear from sales reports.
Reader State Error Event Timeout (MAX: 255 sec) - The unit will wait the defined amount of time before sending the "Reader State Error" alert to the server.
Value can be between 0-255 sec.
If the value is set to "0" - no event will be sent.
MDB Level 3 Optional Features - This Parameter defines the optional features that can be enabled when MDB level 3 mode is set.