LCD Status - Read-Only - Error displayed on the LCD during LCD message "cash only", this parameter is sent every keep alive and shown only if cash only message is under 16 characters.
LCD Message - Read-Only - Message displayed on the LCD which is sent every keep alive.
Welcome Message - This parameter lets you change the VPOS welcome message. The Welcome message is limited to 16 characters per row.
Special features:
%s - will display the unit's own CLI number.
%m - Will display Monyx Machine ID (supported from 3.0.0.4).
\n - Will start a new line.
\f - Will switch between primary and secondary languages.
\0 - End of string
@$ - Use the default Welcome message.
Cash Only Message - This parameter lets you change the VPOS "Cash Only" message. The Welcome message is limited to 16 characters per row.
@$ - Use the default "Cash Only" message.
Choose Product Message - This parameter defines the "Choose Product" Message displayed on VPOS.
@$ - Use the default "Choose Product" message.
Take Product Message - This parameter defines the "Take Product" Message displayed on VPOS.
@$ - Use the default "Take Product" message.
Remove LCD Message - This parameter lets you remove undesired LCD messages.